Warning issued about RBI’s working outside of competence
14th November 2024

Under the Building Safety Act, it is important to understand which class of work your project falls before you can decide which building control body to appoint.
From 6 April 2024, all Building Control Approvers (RBCA) needed to register with the Building Safety Regulator (BSR) to carry out building control activities. Not all Companies were successful in their applications and even those that were limited by the type of work in which they can operate and which building inspectors they can assign to those projects.
This is now starting to cause some issues in the industry and the BSR has recently taken the unusual step of warning Registered Building Inspectors (RBIs) that are operating beyond their certified competence will be investigated and could face penalties. This may constitute professional misconduct and can result in serious consequences for RBIs and their employers, but it can also cause a huge headache for clients if the RBI is sanctioned.
It has recently come to light that some registered building inspectors are not operating at the correct class level in which they are registered. There are strong sanctions in place for those found to be undertaking work they are not registered to do.
Let’s get into it.
The Restricted Activities and Functions Regulations 2023 (RAFR23) introduced the concept of building classes as part of the registration requirements for Registered Building Inspectors.
The RAFR23 has had huge implications for the industry as the functions can now only be undertaken by a competent RBI for each particular building type.
The classifications are detailed by the BSR in a document called the Building inspector competence framework (BICoF). This initially had 4 classifications:
class 1: trainee building inspector
class 2: building inspector
class 3: building inspector
class 4: building inspector (technical manager)
Class 1: these inspectors will be engaged in a training or verification route which may contain academic and/or vocational qualifications. They will work under supervision at a level appropriate to the tasks being undertaken, until they progress to their next registration class.
Class 2: building inspectors perform restricted activities unsupervised within the limitations of their registration. This is a broad class which covers all building types other than non-standard and higher-risk buildings (HRBs).
Some people who register within this class will be working on a limited range of building types. For example, domestic only, and this will be reflected in their registration.
Class 3: building inspectors are those registered with the additional knowledge and experience required to carry out the restricted activities, and advise on restricted functions, in relation to all building types, including non-standard and/or HRBs.
Class 4: building inspectors (technical managers) are those individuals who, in addition to holding the competence of a class 2 or class 3 building inspector, are also responsible for management of a building control team. Class 4 is not a higher class than Class 3.
So far so good!
However, within the classes there are also sub classes – so a RBI may be limited to say Class 2A, meaning they can only deal with single family dwellings up to 7.5m for example.

This is also still quite easy to understand (though definitions of height can at times be complex – always check that you are using the correct measurements, especially on the sloping ground!).
Part of the problem seems to be that some of the early competency schemes didn’t appear to include these sub-classes, leaving inspectors open to determining where within Class 2 they were competent.
Worst still, several inspectors seem unaware that the class 2 registration definition covers all building types other than non-standard and higher-risk buildings (HRBs).
Therefore, a Class 2 RBI cannot only undertake restricted activities or advise on restricted functions for non-standard work (unless under the supervision of a competent Class 3 RBI).
WHAT IS A NON-STANDARD BUILDING?
In order to establish what ‘non-standard’ means, the first step is to determine what is meant by ‘standard’
Standard buildings
Standard buildings have been described by BSR as “buildings designed and constructed from common recognised codes and standards. This can include British Standards, Approved Documents and technical documents such as HTM Codes.”
Non-standard buildings
BSR has confirmed these are buildings which do not follow common recognised codes and standards.
The types of building work classed as non-standard can include those including:
- difficult ground conditions
- buildings designed from first principles
- buildings with unusual occupancies or high levels of complexity (for example, some large mixed-use retail, conference centres and hospitals)
- very large or very tall buildings
- large timber buildings
- buildings that incorporate modern construction methods
Let’s look at some simple examples from our portfolio
Loft conversion with an open plan ground floor
This would be a standard building if it follows the guidance of ADB or BS9991, and assuming it is under 7.5m, this would be a class 2A project. However, if the design departs from that guidance (for example, a water mist system is proposed that doesn’t meet BS8458-1 or the kitchen is not separated), then the building jumps all the way up to class 3G!

https://wilkinsoncc.co.uk/harbour-road-extension/
Three storey modular house construction
Again, this building is under 7.5m in height and follows the guidance in the approved documents, so it initially appears to be another class 2 A project. This method of construction would be considered to be volumetric construction or modular construction. The units would be produced in a controlled environment (such as a factory or warehouse) before being transported to site. This is not a common method of construction and would be considered ”non-standard. Again it would require a class 3G RBI.


Instant House by Westerdahl Architects – currently under construction by Go-Modular
For more information on Modern Methods of Construction see Introducing the MMC Definition
Framework Office fit out of a single floor in a building over 18m in height.
Whilst the work may be standard and comply with the requirements of Approved Document B, the building is over 18m in height and, therefore, automatically falls within class 3.

25 Victoria Street by Parkeray Ltd
Choosing a Building Control Approver
As mentioned above, all building control inspectors must register with the BSR, so when it comes to selecting a building control approver, the first thing you will need to do is ensure that they registered and, secondly, that they have RBIs that can work on your project type as described above.
At Wilkinson Construction Consultants, we have class 2 and class 3 inspectors, which means our team can undertake all types of projects, including non-standard, complex, and unusual projects. In fact, the more unusual the project, the better – there’s nothing standard or boring about our portfolio!
https://wilkinsoncc.co.uk/projects/
If you have a complex, unusual or non-standard project requiring a specialist building inspector, rest assured that Wilkinsons have checked and verified the competence of our inspectors so you can be confident that the registrations are genuine not fake and we can handle your project.
Contact us today to see how we can help.
Website: Wilkinson CC
Telephone: 01732 523466
Email: office@wilkinsoncc.co.uk