Killer Homes (Part 5): K is for Killer
12th August 2026 – by Geoff Wilkinson

This is the penultimate article in our Killer Homes series, where we have been looking at some of the biggest risks in our homes and the Building Regulations that are intended to help prevent them.
Stairs
We probably don’t give our stairs much thought. We walk up them, we walk down them, we carry the washing, the shopping, children, cups of tea and anything else that needs getting from one floor to another. For most of us, using the stairs is so routine that we barely think about it, yet they can be one of the most dangerous parts of our homes.
RoSPA estimates that at least 700 people die every year as a result of falling on domestic stairs with more than 1,000 hospital admissions and around 14,000 injuries resulting in attendance at A&E. With an additional estimated 100,000 leisure industry stair falls and 1,000 workplace injuries on stairs, an injury on stairs maybe occurring on average every 70-80 seconds.
Those are not just statistics about old, poorly maintained houses. People are still suffering serious injuries and dying on staircases in relatively modern homes. ROSPA figures indicate that more than 30 people die every year on domestic stairs built since 2010 and designed in accordance with Part K!
So, if those stairs have been designed and constructed under modern Building Regulations, it raises an uncomfortable question: why?
Part K is the minimum standard
The Government’s Approved Document K guidance is therefore the obvious starting point when designing or checking a staircase. It provides the regulatory framework intended to protect people from falls and other injuries. But there is an important distinction between meeting the minimum regulatory requirements and designing a staircase that is as safe as it reasonably can be.
That is where RoSPA’s Safer by Design approach becomes particularly interesting. It looks beyond simply meeting the Building Regulations and considers what can be done through better design to reduce the risk of accidents and serious injury.
The Government has recognised this issue. In October 2025, it published research into potential changes to the domestic stair guidance in Approved Document K. The research specifically examined step dimensions, consistency and handrail provision as part of its review of stair safety.
You can read the Government’s research into domestic stair design here.
Frequently seen issues
Some of the most frequent issues we see on projects are
- Inadequate landings – the depth of the landing should be at least as deep as the stair is wide – for example a 900mm wide stair should have a 900 x 900 mm landing
- Location of doors – doors should not swing across stairs and landings, and especially do not place a door on the line of a step
- Inadequate or non continuous handrails – handrails should be gripable and continuous – the top of a laminated glass panel does not provide a suitable handrail
- Poorly designed winders – ADK does not provide clear guidance whereas British Standard BS 5395-1 (BSI, 2010) describes in some detail how winders can be designed to have a central going of equivalent size to the going
- Failure to mark the nosing’s in commercial stairs as its not visually pleasing – despite this being a significant factor in misjudging steps

Potential Changes
If we know that people continue to fall on stairs built to current standards, shouldn’t we be asking what else can reasonably be done to reduce that risk?
Rise & Going
Good design needs to consider how people actually use buildings. Someone may be carrying a child or a basket of washing, be elderly or have poor eyesight or balance, be using it in the middle of the night when the lighting is poor or simply be distracted.
A staircase is often forgotten in the early stages of design and ends up having to fit into the building rather than something that is properly designed as part of it. The rooms are arranged, the structure is worked out and then the staircase is squeezed into whatever space is left. Often this results in requests to “relax the requirements” due to inadequate headroom, or because the stair will be too steep.
The rise and goings of the stair are critical to this. Here the Government research is very interesting as users when asked if they felt safe using a stair with a going between 150mm and 275mm deep, the users reported that the increased depth resulted in a greater feeing of safety, but over 275mm there was no significant increase in that sensation. Stairs built to the maximum pitch (42°) recommended in the current building regulation guidance results in a range of expected stair goings (220 mm to 244 mm), but when increased to 250 mm to 260 mm risk was reduced by approximately 60%.
Increasing the minimum going for domestic stairs to 275 mm, or 280 mm as supported in the USA, reduces the risk by 97.2%. A reduction in rise height from 220 mm maximum to 200 mm maximum may increase the flight length by one additional step. If the minimum going is increased by 30 mm, to 250 mm, at a width of 900 mm, requires an additional 0.55 m2 of space given over to circulation.
Handrails
A person who loses their balance wil instinctively reach for something to steady themselves. A properly positioned and usable handrail can help them recover their balance before a small mistake becomes a serious fall. The Government’s recent stair research looked specifically at handrail provision and how people interact with stairs. Most of the research relating to handrails has considered the size, shape and location of the handrail above the pitch line. However the latest research also considered the number of handrails. The findings suggested that two handrails were preferred especially as users have a preferred hand to use to hold onto the handrail, or if they are carrying something can use the other hand for guidance and support. It was clear from the analysis that a stair with no handrails had a risk ratio 2.2 times that of a stair with two handrails. Adding a second handrail to stairs built to the current building regulations has the potential to save the NHS £800k per annum.
Lighting
A staircase that looks perfectly safe during the day can feel very different at two o’clock in the morning. Lighting, contrast and the visibility of the stair nosings might not be the first things considered when designing a staircase, but they are all part of how safely people actually use it. RoSPA’s wider home safety advice recommends keeping stairways well lit and free from clutter to reduce the risk of slips, trips and falls.
The staircase that looked fine on the drawing
We’ve seen plenty of staircases that look perfectly reasonable on a drawing, only for things to change during construction. Finished floor levels change, floor build-ups are altered, details are revised or a staircase is manufactured to slightly different dimensions.
Individually, some of those changes might appear insignificant. But when they affect the rise and going of a staircase, they can change a complaint stir to a non-compliant one.
Conclusion
Part K provides the regulatory framework, but good stair design is about more than ticking boxes. It is about consistency, usability, handrails, visibility and considering how people actually behave when they use the building.
Ultimately, it is about designing out the opportunity for a simple misstep to become a life-changing accident. We can expect significant changes when Part K is revised but don’t wait for the Regs to change make sure that you are designing stairs with safety in mind and don’t try to reduce down the existing guidance for aesthetic reasons, the guidance isn’t there for fun – it might just save a life.
One more to go…
This is the penultimate article in our Killer Homes series. We’ve looked at a number of the risks that can turn an ordinary home into a dangerous one, and the Building Regulations that are intended to help prevent them.
Keep an eye out in September when we’ll bring the series to a close with our final Killer Homes article.