Killer Homes: Part 2
13th January 2026

In our October competition we set out the biggest causes of death in UK homes, and promised to run a series of blogs setting out the risks, and how Building Regs apply.
This month we look at Electrical Shocks and the application of Part P.
Sub-standard electrical installation work and incompetence can and do result in death, injury and loss of property through electric shock and fire.
Introduced in 2005, Part P of the Building Regulations has provided the legal framework to significantly reduce these risks. The Regulatory Impact Assessment for Part P, published in 2004, found that for the period 1990 to 1999 there were around 5 electric shock fatalities and 575 non-fatal electric shock injuries. Data cited in a 2012 Parliament submission showed that Part P contributed to a 17.5% reduction in fires caused by mains wiring over the period 2004–2008, and a reduction down to 227 injuries attributed to faulty installations, although the number of deaths was relatively unchanged.
Following amendments in April 2013, the definition of notifiable work was refined. Electrical work is notifiable (requiring certification and building control notification) when it includes the installation of a new circuit or alterations to existing circuits in special locations such as bathrooms, swimming pools, or saunas. Non-notifiable work includes repairs, maintenance, replacements, and minor additions outside special locations. Crucially, non-notifiable work still must meet BS 7671 and Part P requirements. The absence of notification reflects a proportionate risk assessment, not a lower safety standard. Members of a ‘Competent Person Scheme’ are able to self-certify their own work but must have an appreciation of how the Building Regulations in general affect their electrical installation work, just Part P. for example fire stopping cabling so as not to detrimentally affect fire safety or ensuring any notches in floor joists do not affect the structural integrity of joists etc.
All buildings requiring electricity will have cables running through and along walls. In addition, the installation of sockets and power points will require electric cables, and no one wants all of this wiring exposed due to both how it looks and how vulnerable to damage it could be. As you can imagine, running cables just behind walls in a haphazard fashion could be equally dangerous. That’s because eventually, someone may want to drill, hammer or cut into the wall, resulting in both a loss of power and the potential for serious injury. Until regulations were introduced, cables were installed in a less regimented and less uniform manner, which is why you need to work very carefully in some older buildings.
For many designers there is little thought given to electrical design, with the assumption that a competent person will be installing and certifying the installation. However there are several areas where design should consider how the electrical installation will be achieved.
For example, it’s important to consider where the electrical safe zones are for walls according to the BSI (British Standards Institution).
Along the top of the wall. This zone runs along the area where the wall meets the ceiling and is a 150mm-thick strip.
Where walls meet.
Corners where walls meet are considered safe zones, again at 150mm depth on either side of where they meet, whether they’re internal or external. This zone runs up the length of the wall, from floor to ceiling.
Where electrical accessories are installed.
Where an electrical accessory is located, such as a socket or light fitting, the cables should be run in a straight line vertically, both above and below it, or horizontally on either side in a straight line. This applies to the wall on which the installation sits only, it does not carry on around any corners.
A key consideration for designers is to ensure that any specified fittings are suitable for the zone in which they are proposed to be used. This is especially the case with the increase in imported items from China and products purchased from China. Part P divides bathrooms into Zone 0 (inside bath/shower), Zone 1 (above Zone 0 to 2.25m), and Zone 2 (60cm around Zone 1), with each zone requiring specific IP-rated (waterproof) electrical equipment, like IPX4 or IPX7.
One last issue we often discover is that there can be a contractual dispute with the electrician, or they can become insolvent, lose accreditation, or even in some cases pass away. We know that many building control bodies exclude coverage of the electrical assuming that it will be covered under the Part P competent person scheme. In such cases the Competent person scheme no longer applies, and clients can find that neither building control nor the electrician have signed off the work. That’s why at Wilkinsons we don’t exclude electrical work automatically on our notices and why we ask for test certificates at the end of the project, that way if a Part P electrician can’t cover the work, we can at least sign off with a EICR check by another qualified electrician.