Confusion over the requirements for HMO’s
15th April 2025

We have seen an increase in the number of applications recently submitted for houses in multiple occupation (HMO), which fall outside of the guidance used by Building Control to determine compliance.
The term HMO comes from the Housing Act 2004 and causes confusion as the term does not appear anywhere within the Building Regulations or within the Approved Documents. In the building regulations, such buildings are either houses, flats or other residential use, and the requirements relevant are determined accordingly.
The degree to which the requirements apply also depends on whether or not the works are a conversion, an extension or a change of use – or a combination of the above.
Houses
Starting with the definition of a house – this is defined as a unit where one or more people live (whether or not as a sole or main residence) in either of the following situations.
- A single person or people living together as a family.
- A maximum of six people living together as a single household, including where care is provided for residents.
As such, as soon as a proposal for a HMO exceeds 6 people (as opposed to 6 bedrooms) the building is not classified as a house, so cannot therefore be a house in multiple occupation.
Flats
Flats are self-contained units of accommodation, and as such, shared facilities such as a shared kitchen, lounge or bathroom are indicators that the proposed HMO is not a flat. However, if the HMO has its own bathroom and cooking facilities, then that is likely to mean it is classed as a flat – even if there is a shared facility. For example, think of a block of flats with a gym – that would not be a HMO.
Other Residential
Assuming that the HMO proposal doesn’t fall within the above, then it’s likely that it will be classed as other residential – purpose group 2 b, and this is the guidance that should be used for your proposal.
In 2019, the BCA published a handy flowchart to help explain which requirements apply to your proposal.

Notes
- This chart does not cover conversions to residential (institutional) use
- Other requirements may apply such as A1 to A3 depending on the scope of the proposed work
- It is for the Principal Designer to set out how the proposal will meet the relevant requirements, however, we will not generally accept LACORS guidance on buildings falling outside of the dwelling definition as an alternative to the Approved Documents or British Standards. NB LACORS guidance was intended for assessment of existing buildings rather than new works/new conversions.